Fire-resistant rolling doors
Release time:
2026-03-23
Fire-rated rolling shutters are fire-resistant and heat-insulating devices designed for large openings in buildings. Common types of fire-rated rolling shutters include steel fire-rated rolling shutters, inorganic fiber composite fire-rated rolling shutters, and Class A fire-rated rolling shutters. Fire-rated rolling shutters are widely used for fire compartmentation in industrial and commercial buildings.

The main types of fire-resistant rolling doors include composite steel fire-resistant rolling doors (fire and smoke resistant), inorganic Class A fire-resistant rolling doors (dual-track, dual-curtain), composite steel water-spray and mist-type fire-resistant rolling doors, composite steel side-opening fire-resistant rolling shutters, composite steel horizontal-opening fire-resistant rolling shutters, inorganic Class A folding fire-resistant rolling shutters, and fire-resistant rolling shutters with various internal doors.
By material
Steel, composite, inorganic, etc.
By installation type
In-wall and side-wall (also known as inside the opening and outside the opening).
By opening direction
Upward-rolling and side-rolling.
There is currently no national standard for the fire resistance rating of fire-resistant rolling shutters. GB 14102, “General Technical Requirements for Steel Fire-Resistant Rolling Shutters,” classifies ordinary steel fire-resistant rolling shutters as follows: However, the currently enforced standard is GB 14102-2005, “Fire-Resistant Rolling Shutters.”
Class 1: Fire resistance rating of 1.50 hours
Class F2: Fire resistance rating of 2.0 hours
Function
Fire-resistant rolling shutters serve the same function as firewalls in providing horizontal fire compartmentation. They consist of 13 components: slats, base plate, guide rails, brackets, roller shaft, housing, control box, rolling door operator, limit switches, lintel, manual quick-release switch, push-button switch, and safety device. They are generally installed in areas where firewalls are impractical. Examples include open elevator lobbies, escalators, spacious sales floors in department stores, exhibition halls in exhibition buildings, and areas within buildings where openings are too large to accommodate fire-rated doors or windows. Fire-rated rolling shutters have found widespread application in construction projects for fire compartmentation.
Fire-rated rolling shutters are indispensable fire protection facilities in modern high-rise buildings. In addition to serving the functions of ordinary doors, they possess special capabilities such as fire resistance, smoke containment, suppression of fire spread, and protection of personnel evacuation. They are widely used in high-rise buildings, large shopping malls, and other densely populated areas.
Functionality and Performance
Fire-rated rolling shutters are based on standard steel rolling shutters, with modified drive components and integrated fire-rated electrical equipment to achieve fire protection: The fire-rated motor is controlled by a fire-rated control panel and drives the roller shaft via a speed-regulating mechanism to open and close the shutter. In the event of a power outage, the manual crank on the fire-rated motor allows for manual operation. At points of mechanical relative motion, couplings are used instead of sprocket drives, and copper plates or nylon are embedded in the friction points of the guide rails. They are most suitable for factories and warehouses where highly flammable items such as combustible gases and volatile chemicals are used or stored—environments where there is a risk of fire or explosion.
1. An integrated bus system is used internally, ensuring reliable and rapid data transmission.
2. Features automatic phase sequence detection, correction, and phase loss protection. Includes automatic switching between main and backup power sources (with backup power).
3. Equipped with a variety of reserved interfaces for integration with fire control centers.
4. Fully electronic learning and memory-based limit positioning ensures absolute precision; upper and lower limit positions remain constant.
5. Utilizes advanced microprocessor technology for stable and reliable operation with no upper height range limitations.
6. Features synchronous and step-by-step detection of smoke and temperature sensor signals.
7. Operation parameter settings are simple, convenient, and accurate.
8. Equipped with a manual override escape function. In the event of a three-phase power failure or main power failure, the controller can activate the rapid-release mechanism to automatically lower the roller shutter, thereby closing it.

Composite Classification
Class F3, fire resistance rating: 3.00 hours
Class F4, fire resistance rating: 4.00 hours
However, the national standard GB 14102 for the fire resistance classification of steel fire-rated rolling shutters does not require measuring the temperature rise on the non-fire side during fire resistance testing, nor does it use the temperature rise on the non-fire side as a criterion for determining the fire resistance rating. In recent years, vapor-type steel fire-resistant rolling shutters and evaporative vapor-type steel fire-resistant rolling shutters have appeared on the market. According to the requirements of the “High-Rise Building Fire Protection Code,” when used as components for fire compartmentation, the temperature rise on the non-fire side must be used as the criterion for determining the fire resistance rating. To distinguish between the fire resistance ratings of fire-resistant rolling shutters based on these two different evaluation criteria, experts overseeing the “High-Rise Building Code” have recommended the following prior to the issuance of the national standard for fire-resistant rolling shutter classification: Fire-resistant roller shutters that undergo fire resistance testing in accordance with the national standard “Test Methods for Fire Resistance of Doors and Roller Shutters” (GB 7633), meet all evaluation criteria—including the temperature rise on the non-fire side—and achieve a fire resistance rating of ≥3.0 hours shall be designated as “Special Grade” fire-resistant roller shutters. All fire-resistant roller shutters for which the temperature rise on the non-fire side is not used as an evaluation criterion in fire resistance testing shall be collectively referred to as “Standard Grade” fire-resistant roller shutters.
Where are fire-rated rolling doors typically installed?
Installation is determined by the building design. In addition to being installed in firewalls, fire-rated rolling doors should also be installed between two fire compartments where no firewall exists. They are generally installed in the following locations.
(1) Enclosed stairwells leading to corridors; enclosed elevator shafts; and doors from elevator lobbies to corridors.
(2) Inspection doors of vertical shafts such as cable shafts, utility shafts, smoke exhaust ducts, and garbage chutes.
(3) Doors in firewalls and fire partitions established to delineate fire compartments and control the floor area of such compartments. When it is difficult to install firewalls or fire doors in a building, fire-rated rolling doors shall be used as a substitute, and must be protected by a water curtain.
(4) Partition doors and unit entrance doors required by standards (such as GB50045-95 “Code for Fire Protection Design of High-Rise Civil Buildings”) or by specific design requirements for fire and smoke protection. For example: partition doors in equipment rooms for fixed fire extinguishing systems (cylinder rooms, foam stations, etc.) and in ventilation and air-conditioning plant rooms within high-rise civil buildings shall be Class A fire-rated doors; Doors in partition walls of basement rooms where people frequently stay or where there is a large amount of combustible material shall use Class A fire-rated doors; where conditions necessitate the installation of oil- or gas-fired boilers, oil-immersed power transformers, high-voltage capacitors filled with combustible oil, or switches in high-rise buildings, the doors in the partition walls of these dedicated rooms shall all use Class A fire-rated doors. Additionally, for unit entrance doors with special fire protection requirements—such as those in fire control and command centers, archives, and warehouses for valuable items—Class A or Class B fire-rated doors are typically selected. Unit entrance doors in high-rise luxury residential buildings often use fire-rated and burglar-proof doors.

These are primarily used in public spaces with fire safety requirements, such as large supermarkets (hypermarkets), large shopping malls, large specialty material markets, large exhibition halls, factories, and warehouses. When a fire alarm is triggered, fire-resistant rolling doors, controlled by the central fire control system, automatically lower (descend) according to a pre-set program, thereby preventing the spread of flames to other areas and buying valuable time for firefighting operations.
Under normal circumstances, large buildings are equipped with a central fire control system in accordance with national fire safety regulations. When a fire occurs, smoke detectors installed on the ceiling first detect smoke signals and simultaneously alert the central control system. After verification, the central fire control system activates the power supply to the fire-rated rolling shutter in the affected area, causing it to descend at a predetermined speed. When the door reaches a position approximately 1.5 meters above the floor, it stops descending to facilitate the evacuation of occupants. After remaining stationary for a set period, the fire-rated rolling shutter door continues to descend until fully closed. The descent speed and intermediate pause duration can be adjusted during installation.
In some cases, buildings are not equipped with a central fire control system, and the fire-rated rolling shutter door relies solely on its own fire control electrical box to execute the prescribed fire safety operation procedures. In such situations, when a fire alarm is triggered, the alarm signal received by the smoke detector is transmitted directly to the fire control electrical box of the fire-rated rolling shutter door.
In the event of a power outage, the fire-rated rolling shutter door can only be lowered by pulling the chain. The manual operation mechanism of fire-rated rolling shutters is designed for one-way lowering only and cannot be used for raising.
Fire-rated rolling shutters have stringent manufacturing requirements; specifically, the entire system must withstand temperatures of approximately 1,100°C for a specified duration. The fire resistance rating is a key performance indicator for these shutters. The General Technical Requirements for Steel Fire-Rated Rolling Shutters (GB 14102-93) defines four fire resistance ratings.
Operational Details to Note During the Use of Fire-Rated Rolling Shutters
Steel fire-rated rolling shutters are critical fire safety facilities for fire compartments and fire barriers in public spaces. As fire safety products that integrate mechanical and electrical functions, installed fire-rated rolling shutters must always remain in proper working order. During operation, dedicated equipment must be operated and maintained by designated personnel who possess basic knowledge of electrical and mechanical systems.
During operation, operators must not leave their posts without authorization. They should closely monitor the opening and closing processes and ensure proper execution. No one is permitted to stand or walk beneath the curtain during operation to prevent malfunctions such as failed limit switches, curtain jamming, motor obstruction, or other accidents. Steel fire-resistant rolling shutters used for fire compartments and fire barriers are not intended for frequent use under normal conditions; however, they must be effectively deployed in the event of a fire in the area. Automatic fire-resistant rolling shutters equipped with interlocking controls or controlled by a central control center must operate strictly in accordance with a set of control instructions.
If any abnormalities are detected during operation, emergency measures must be taken immediately to cut off the power supply and troubleshoot the issue. A regular maintenance schedule must be established for fire-rated rolling shutters, and maintenance records for each unit must be kept and filed. Shutters that remain unused for extended periods must be maintained at least once every six months, which includes removing dust, applying paint, and lubricating the sprockets and roller chains of the drive mechanism. Inspect electrical circuits and equipment for damage, verify normal operation, and ensure compliance with all operational requirements. If any damage or non-compliance is found, repairs must be performed immediately.
Latest News
Is laminated glass actually worth installing? Decide after reading this.
1. High safety performance: Upon breakage, fragments adhere to the interlayer, preventing them from scattering and causing injury. 2. Sound insulation and noise reduction: The interlayer effectively blocks external noise. 3. UV protection: Blocks the majority of ultraviolet rays, preventing the fading of interior finishes and furnishings. 4. Shock and explosion resistance: Offers high impact resistance, ensuring the structure remains intact even when subjected to a blow. 5. Can be customized for specialized requirements such as bullet resistance and fire protection, making it suitable for high-end projects.
2026-11-12
The Upsides and Downsides of Enamel Soup Pans
Image Source: statics.mylandingpages.co An enamel soup pan delivers even, non-reactive heating and easy cleaning, yet it feels heavier, costs more, and demands careful handling. The pros and cons favor soups, stews, and acidic recipes. This cookware suits gentle simmering far better than high-heat searing or rough daily use. Key Takeaways E
2026-11-10
Would you like to know more about antique mirror?
Antique silver mirror features unique natural aged textures created by etching & oxidation. Custom finishes, colors, sizes and tempering are available. Durable coating-integrated vintage effect, ideal for interior decoration projects.
2026-11-05